WD Solar Inverter DC to AC,700W-40KW
◤WD SOLAR INVERTER DC TO AC 700W-40KW:
★ Solar Dc to Ac Inverter pure sine wave output
Advantages of a pure sine wave inverter: The output waveform is good, very friendly for component operation, with low distortion. The loaded waveform can also be perfectly output. The waveform is basically consistent with the mains waveform. In fact, a good pure sine wave inverter provides higher quality AC power than the power grid.
★ High efficiency toroidal transformer lower loss
The main advantages of toroidal transformers are low radiation field and high efficiency. The toroidal transformer has a high degree of flexibility, can be designed according to the requirements of the chassis and overall assembly, and has low noise retention.
★ LCD integration displays inverter various states
The inverter with LCD display function facilitates users to timely understand whether the inverter is working properly. It can also alert users of abnormal inverter operation through a buzzer alarm.
★ AC charge current 0-20A adjustable; battery capacity configuration more flexible
The voltage of the battery must be the same as the input voltage of the inverter.
At the same time, in order to ensure that the inverter has sufficient power output, the configured battery capacity should be as large as possible. The larger the capacity, the longer the continuous use time.
Of course, considering the convenience of using the inverter and the acceptability of economic value, it is sufficient to configure a suitable battery capacity.
★ Three types working modes adjustable:main priority, battery priority, and pv priority
In an off grid solar storage system, the operating modes of inverters can be divided into three types. They are: main priority, battery priority, and pv priority. This is determined based on their application scenarios and actual needs. Different modes of inverters are set according to various requirements. Work to maximize solar energy resources.
★ Frequency adaptive function, adapt to different grid environments
The inverter can adapt to harsh grid environments such as high temperature, cold, and humidity to protect the normal operation of the equipment.
★ Added fault code query function,facilitate user to monitor the operation state in real time
1. The main function of the inverter monitoring system is to collect inverter data, monitor the operation status, fault detection, early warning, etc, and obtain real-time operation data of the inverter.
2. The inverter monitoring system can realize real-time monitoring of the operation status of the inverter, timely detect faults, facilitate maintenance personnel to timely handle faults, and improve the reliability and safety of the inverter.
★ Supports diesel or gasoline generator, adapt any tough electricity situation
While supporting solar and main power input, it can also support the input of diesel and gasoline generators, allowing flexible power consumption and ensuring the normal operation of electrical appliances.
★ RS485 communication port/APP optional
The inverter provides a variety of parameter configurations, and users can configure parameters through the mobile app to meet various needs or adjust its operating performance to the best.
The RS485 communication port is used to access the communication module of the Hinton power and upload monitoring data to the monitoring background through wireless communication.
After the inverter successfully establishes communication, the user can view the relevant information of the inverter or set the operation, protection, and other parameters of the inverter through the management platform.

WD 700W-40KW solar dc to ac inverter Wiring diagram
◤WP SOLAR INVERTER FOR SOLAR SYSTEM OEM/ODM:
XINDUN power,the Most Reliable Manufacturer in China of solar inverter and power inverter for solar panel system,more than 16 Years of Production,Design and R&D Experience.Suitable for Global customers,personal use or for agents to select suppliers.Welcome customize order with LOGO design or outlook design.Special voltage,power and appearance can be customized according to the users.Accept OEM/ODM.
Please contact XINDUN our sales for more about solar inverter for solar system.

WD dc to ac inverter solar factory

WD solar inverter dc to ac- Customer Case

WD dc to ac inverter solar case
◤WP POWER INVERTER FOR SOLAR PANEL SYSTEM SPECIFICATIONS:
Specification | |||||||||||
Model WD/WD-T | 70112/24 (701) |
10212/24 (102) |
15224/48 (152) |
20224/48 (202) |
30224/48 (302) |
35248/96 (352) |
40248/96 (402) |
50248/96 (502) |
60248/96 (602) |
70248/96/192 (702) |
|
Rated Power | 700W | 1000W | 1500W | 2000W | 3000W | 3500W | 4000W | 5000W | 6000W | 7000W | |
Peak Power(20ms) | 2100VA | 3000VA | 4500VA | 6000VA | 9000VA | 10500VA | 12000VA | 15000VA | 18000VA | 21000VA | |
Start Motor | 0.5HP | 1HP | 1.5HP | 2HP | 3HP | 3HP | 3HP | 4HP | 4HP | 5HP | |
Battery Voltage | 12/24VDC | 12/24VDC | 24/48VDC | 24/48VDC | 24/48VDC | 48/96VDC | 48/96VDC | 48/96VDC | 48/96VDC | 48/96/192VDC | |
Max AC charging current | 0A~20A(Depending on the model,The maximum charging power is 1/4 of the rated power) | ||||||||||
Built-in solar controller charging current (optional) | 10A~60A(PWM or MPPT) | 24/48V(PWM:10A~60A/MPPT:10A~100A) | 48V(PWM:10A~120A/MPPT:10A~100A) / 96V(50A/100A(PWM or MPPT)) |
||||||||
Size(L*W*Hmm) | 340x165x283 | 410x200x350 | 491x260x490 | ||||||||
Packing Size(L*W*Hmm) | 405x230x340(1pc) / 475x415x350(2pc) | 475x265x410 | 545x315x550 | ||||||||
N.W.(kg) | 9.5(1pc) | 10.5(1pc) | 11.5(1pc) | 17 | 20.5 | 21.5 | 29 | 30 | 31.5 | 36 | |
G.W.(kg) | 11(1pc) | 12(1pc) | 13(1pc) | 19 | 22.5 | 23.5 | 32 | 33 | 34.5 | 39 | |
Installation Method | Tower | ||||||||||
Model WD | 80248/96/192 (802) |
10348/96/192 (103) |
12396/192 (123) |
153192 (153) |
203192 (203) |
253240 (253) |
303240 (303) |
403384 (403) |
|||
Rated Power | 8KW | 10KW | 12KW | 15KW | 20KW | 25KW | 30KW | 40KW | |||
Peak Power(20ms) | 24KVA | 30KVA | 36KVA | 45KVA | 60KVA | 75KVA | 90KVA | 120KVA | |||
Start Motor | 5HP | 7HP | 7HP | 10HP | 12HP | 15HP | 15HP | 20HP | |||
Battery Voltage | 48/96/192VDC | 48/96V/192VDC | 96/192VDC | 192VDC | 192VDC | 240VDC | 240VDC | 384VDC | |||
Max AC charging current | 0A~40A(Depending on the model,The maximum charging power is 1/4 of the rated power) |
0A~20A(Depending on the model,The maximum charging power is 1/4 of the rated power) | |||||||||
Built-in solar controller charging current (optional) | PWM:(48V:120A;96V:50A/100A;192V/384V:50A) MPPT:(48V:100A/200A;96V:50A/100A;192V/384V:50A) | 50A/100A | 50A/100A | ||||||||
Size(L*W*Hmm) | 540x350x695 | 593x370x820 | 721x400x1002 | ||||||||
Packing Size(L*W*Hmm) | 600*410*810 | 656*420*937 | 775x465x1120 | ||||||||
N.W.(kg) | 66 | 70 | 77 | 110 | 116 | 123 | 167 | 192 | |||
G.W.(kg) | 77 | 81 | 88 | 124 | 130 | 137 | 190 | 215 | |||
Installation Method | Tower | ||||||||||
Input | DC Input Voltage Range | 10.5-15VDC(Single battery voltage) | |||||||||
AC Input Voltage Range | 73VAC~138VAC(110VAC)/ 83VAC~148VAC(120VAC) / 145VAC~275VAC(220VAC) / 155VAC~285VAC(230VAC) / 165VAC~295VAC( 240VAC) (700W~7000W) 92VAC~128VAC(110VAC) / 102VAC~138VAC(120VAC) / 185VAC~255VAC(220VAC) / 195VAC~265VAC(230VAC) / 205VAC~275VAC( 240VAC) (8KW~40KW) |
||||||||||
AC Input Frequency Range | 45Hz~55Hz(50Hz)/ 55Hz~65Hz(60Hz) | ||||||||||
AC charging method | Three-stage (constant current, constant voltage, floating charge) | ||||||||||
Output | Efficiency(Battery Mode) | ≥85% | |||||||||
Output Voltage(Battery Mode) | 110VAC±2% / 120VAC±2% / 220VAC±2% / 230VAC±2% / 240VAC±2% | ||||||||||
Output Frequency(Battery Mode) | 50Hz±0.5 or 60Hz±0.5 | ||||||||||
Output Wave(Battery Mode) | Pure Sine Wave | ||||||||||
Efficiency(AC Mode) | >99% | ||||||||||
Output Voltage(AC Mode) | 110VAC±10% / 120VAC±10% / 220VAC±10% / 230VAC±10% / 240VAC±10%(700W~7000W); Follow input(8KW~40KW) | ||||||||||
Output Frequency(AC Mode) | Follow input | ||||||||||
Output waveform distortion (Battery Mode) |
≤3%(Linear load) | ||||||||||
No load loss(Battery Mode) | ≤1% rated power | ||||||||||
No load loss(AC Mode) | ≤2% rated power( charger does not work in AC mode) | ||||||||||
No load loss (Energy saving Mode) |
≤10W | ||||||||||
Battery Type (selectable) |
VRLA Battery | Charge Voltage :14.2V; Float Voltage:13.8V(Single battery voltage) | |||||||||
Customize battery | Charging and discharging parameters of different types of batteries can be customized according to user requirements (charging and discharging parameters of different types of batteries can be set through the operation panel) |
||||||||||
Protection | Battery undervoltage alarm | Factory default: 11V(Single battery voltage) | |||||||||
Battery undervoltage protection | Factory default: 10.5V(Single battery voltage) | ||||||||||
Battery overvoltage alarm | Factory default: 15V(Single battery voltage) | ||||||||||
Battery overvoltage protection | Factory default: 17V(Single battery voltage) | ||||||||||
Battery overvoltage recovery voltage | Factory default: 14.5V(Single battery voltage) | ||||||||||
Overload power protection | Automatic protection (battery mode), circuit breaker or insurance (AC mode) | ||||||||||
Inverter output short circuit protection | Automatic protection (battery mode), circuit breaker or insurance (AC mode) | ||||||||||
Temperature protection | >90°C(Shut down output) | ||||||||||
Alarm | A | Normal working condition, buzzer has no alarm sound | |||||||||
B | Buzzer sounds 4 times per second when battery failure, voltage abnormality, overload protection | ||||||||||
C | When the machine is turned on for the first time, the buzzer will prompt 5 when the machine is normal | ||||||||||
Inside Solar controller (Optional) |
Charging Mode | PWM or MPPT | |||||||||
PV Input Voltage Range | PWM: 15V-44V(12V system); 30V-44V(24V system); 60V-88V(48V system); 120V-176V(96V system);240V-352V(192V system) ;300V-400V(240V system); 480V-704V(384V system) MPPT: 15V-120V(12V system); 30V-120V(24V system); 60V-120V(48V system); 120V-240V(96V system);240V-360V(192V system);300V-400V(240V system);480V-640V(384V system) |
||||||||||
Max PV Input Voltage(Voc) (At the lowest temperature) |
PWM: 50V(12V/24V system); 100V(48V system); 200V(96V system);400V(192V system);500V(240V system) ;750V(384V system) MPPT: 150V(12V/24V/48V system); 300V(96V system);450V(192V system);500V(240V system) ;800V(384V system) |
||||||||||
PV Array Maximum Power | 12V system: 140W(10A)/280W(20A)/420W(30A)/560W(40A)/700W(50A)/840W(60A)/1120W(80A)/1400W(100A); 24V system: 280W(10A)/560W(20A)/840W(30A)/1120W(40A)/1400W(50A)/1680W(60A)/2240W(80A)/2800W(100A); 48V system: 560W(10A)/1120W(20A)/1680W(30A)/2240W(40A)/2800W(50A)/3360W(60A)/4480W(80A)/5600W(100A)/6720W(PWM 120A)/5.6KW&11.2KW(MPPT 100A/200A); 96V system: 5.6KW(50A)/11.2KW(100A);192V system: (PWM:11.2KW(50A)/22.4KW(100A)) / (MPPT:11.2KW(50A)/11.2*2KW(100A)); 240V system: (PWM:14KW(50A)/28KW(100A)) / (MPPT:14KW(50A)/14*2KW(100A));384V system: (PWM:22.4KW(50A)/44.8KW(100A)) / (MPPT:22.4KW(50A)/22.4*2KW(100A)) |
||||||||||
Standby loss | ≤3W | ||||||||||
Maximum conversion efficiency | >95% | ||||||||||
Working Mode | Battery First/AC First/Saving Energy Mode | ||||||||||
Transfer Time | ≤4ms | ||||||||||
Display | LCD | ||||||||||
Thermal method | Cooling fan in intelligent control | ||||||||||
Communication(Optional) | RS485/APP(WIFI monitoring or GPRS monitoring) | ||||||||||
Environment | Operating temperature | -10℃~40℃ | |||||||||
Storage temperature | -15℃~60℃ | ||||||||||
Noise | ≤55dB | ||||||||||
Elevation | 2000m(More than derating) | ||||||||||
Humidity | 0%~95% ,No condensation | ||||||||||
Note: All specifications are subject to charge without prior notice |
XINDUN Power – China’s manufacturer and supplier of solar inverter for solar system. We only provide high-quality Power Inverter and Solar Inverter to global customers, including importers, wholesalers, agents, retailers and individual users.If you want to find power inverter for solar panel system suitable for your market and the appropriate inverter price, please feel free to contact our inverter sales experts, and we will help you succeed in the Inverter market.